drawing

  • Protection Class I.
  • Isolation Class T50/B.
  • Separate Primary/Secondary windings.
  • Ground connection.
  • Dielectric rigidity:
    • 4000V between windings.
    • 2000V between windings and mass.
  • Available voltages: Primary -110 up to 500 v. Secondary 12 - 24 - 42 - 48 - 110 v.
    • Any other voltages on demand.

MATERIALS:

  • Enamelled copper wire Grade 2 Class H / IEC 317.
  • Magnetic core of cold laminated plate V 350-50 A DIN 46.400.
  • Coils of composite polyamid 6 with 30% fiber glass reinforcement.

PHYSICAL SPECIFICATIONS FOR A PRIMARY AND A SECONDARY TRANSFORMERS

POWER

Ucc

U2

DIMENSIONS (mm)

APP/WEIGHT

(VA)

(%)

(%)

 

A

B

C

D

H

M x N

(Kg.) NET

40

9,2

7,9

0,83

78

72

86

51

44

9 x 4,8

1,01

63

7,0

6,3

0,83

85

76

90

61

46

9 x 4,8

1,40

100

7,0

6,3

0,92

85

91

90

61

57

9 x 4,8

1,85

160

6,5

4,1

0,86

96

94

100

81

66

11 x 5,8

2,54

200

6,1

3,9

0,89

96

97

100

81

69

11 x 5,8

2,73

250

5,6

3,7

0,88

108

99

108

81

71

11 x 5,8

3,56

300

5,5

3,3

0,90

108

105

108

81

75

11 x 5,8

3,95

400

5,3

3,4

0,89

120

105

118

90

79

11 x 5,8

4,94

500

4,9

2,3

0,91

120

115

118

90

88

11 x 5,8

5,73

630

4,3

2,0

0,90

120

127

118

90

98

11 x 5,8

6,67

800

4,9

2,7

0,93

150

114

148

122

86

13 x 7

7,93

1000

4,3

1,4

0,93

150

120

148

122

96

13 x 7

9,34

1600

4,2

2,5

0,94

150

140

148

122

116

13 x 7

12,24

2000

3,8

1,5

0,94

150

160

148

122

135

13 x 7

14,68

2500

4,0

1,1

0,94

195

140

175

150

110

18 x 10

18,34

3000

3,3

1,3

0,96

195

160

175

150

130

18 x 10

22,12

Ucc = short-circuit tension. &endash; U2 = tension losses at full load with cos= 1. &endash; = efficiency at full load with cos= 1.

 

Drawing

Polígono Las Norias, C/  Antonio Barriendos S/N

50540 MUEL ZARAGOZA (SPAIN)

Tel.: +34 976 140 606

Fax: +34 976 140 607

Specifications subjet to change without notice.

Top of the page